ICD-10-PCS Code Range for Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

ICD-10-PCS Code Range for Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device is medical classification list by Centers for Medicare and Medicaid Services (CMS).

ICD-10-PCS code range (0WW), contains ICD-10-PCS codes for Central Nervous System and Cranial Nerves, Medical and Surgical, Anatomical Regions, General, Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

Image 2
PCS Tables

0WW

0 Medical and Surgical
W Anatomical Regions, General
W Revision: Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Body Part Approach Device Qualifier
Character 4 Character 5 Character 6 Character 7
Body System (Character 4)
0 Head
2 Face
4 Upper Jaw
5 Lower Jaw
6 Neck
8 Chest Wall
F Abdominal Wall
K Upper Back
L Lower Back
M Perineum, Male
N Perineum, Female
Approach (Character 5)
0 Open
3 Percutaneous
4 Percutaneous Endoscopic
X External
Substance (Character 6)
0 Drainage Device
1 Radioactive Element
3 Infusion Device
7 Autologous Tissue Substitute
J Synthetic Substitute
K Nonautologous Tissue Substitute
Y Other Device
Qualifier (Character 7)
Z No Qualifier
Body System (Character 4)
1 Cranial Cavity
9 Pleural Cavity, Right
B Pleural Cavity, Left
G Peritoneal Cavity
J Pelvic Cavity
Approach (Character 5)
0 Open
3 Percutaneous
4 Percutaneous Endoscopic
X External
Substance (Character 6)
0 Drainage Device
1 Radioactive Element
3 Infusion Device
J Synthetic Substitute
Y Other Device
Qualifier (Character 7)
Z No Qualifier
Body System (Character 4)
C Mediastinum
Approach (Character 5)
0 Open
3 Percutaneous
4 Percutaneous Endoscopic
X External
Substance (Character 6)
0 Drainage Device
1 Radioactive Element
3 Infusion Device
7 Autologous Tissue Substitute
G Defibrillator Lead
J Synthetic Substitute
K Nonautologous Tissue Substitute
Y Other Device
Qualifier (Character 7)
Z No Qualifier
Body System (Character 4)
D Pericardial Cavity
H Retroperitoneum
Approach (Character 5)
0 Open
3 Percutaneous
4 Percutaneous Endoscopic
X External
Substance (Character 6)
0 Drainage Device
1 Radioactive Element
3 Infusion Device
Y Other Device
Qualifier (Character 7)
Z No Qualifier
Body System (Character 4)
P Gastrointestinal Tract
Q Respiratory Tract
R Genitourinary Tract
Approach (Character 5)
0 Open
3 Percutaneous
4 Percutaneous Endoscopic
7 Via Natural or Artificial Opening
8 Via Natural or Artificial Opening Endoscopic
X External
Substance (Character 6)
1 Radioactive Element
3 Infusion Device
Y Other Device
Qualifier (Character 7)
Z No Qualifier

January 01, 1970
Novitas and FCSO will require documentation for certain pathology and laboratory claims. Medicare Administrative Contractors MAC Novitas Solutions and First Coast Service Options FCSO recently announc... [ Read More ]
January 01, 1970
Potential erroneous Medicare payments million to treat patients with opioid use disorder OUD are estimated at 17.8 million. The opioid crisis in the United States has led to record numbers of people d... [ Read More ]
January 01, 1970
Get an overview of key updates to the postacute care quality reporting programs for 2025. The Centers for Medicare 38 Medicaid Services is offering a crosssetting webbased training course that provide... [ Read More ]
January 01, 1970
Hospitals should use this tool to protect their profit margins. Diagnosisrelated group DRG validation ensures the accuracy of DRG assignment and payment for inpatient hospital stays. Since inpatient c... [ Read More ]
January 01, 1970
Meet a member who has made an indelible impression in the healthcare industry. AAPCs Member of the Month Nancy Reading RN BS CPC CPCP CPCI is a longtime member and a pillar in the healthcare community... [ Read More ]