Question: The provider removed a foreign body in the throat using the laryngoscope. As there are different foreign body removal codes for services during a laryngoscopy, could you please guide which one to use? Texas Subscriber Answer: There are quite a few code choices to report a foreign body removal during a laryngoscopy. To be precise, you have four codes to report a foreign body removal during a laryngoscopy: For reporting the right procedure by looking through patient documentation, you will need to look for some clues to point you in the right direction. If you see words like “mirror” or “indirect” being used, you are more likely to be seeing a simple procedure of using a mirror to guide your clinician and no scope was used during the procedure. In such a case, you report 31511. Instead, if you see your clinician introducing a scope through the nose to view the structures or are seeing words like “flexible,” “fiberoptic,” or “nasopharyngeal laryngoscopy” in the patient documentation, your clinician has used a flexible fiberoptic scope and you should report the FBR with 31577. Also, an indirect or a flexible laryngoscopy can be performed in your office and does not require general anesthesia. If you see the procedure being performed in the OR, or you see in the patient documentation that the patient received general anesthesia, your clinician is more likely to be performing a direct operative laryngoscopy. So, in such a case, you report 31530. If you observe your clinician used an operating microscope or a telescope for the procedure, you report 31531.